Home >> Mini >> 2013 >> Cooper Clubman, Standard Trans >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Memory Modules >> General Electrical System - Repair (R55) -- Cooper >> Plug Connection, Terminal, Power Distribution Box >> 61 13... Opening plug housings and removing contacts of different plug systems >> 61 13... Socket housing 42-, 43-pin, Hybrid System MQS/MPQ
April 5, 2026: LEMON Manuals is launched! Read the announcement.

61 13... Socket housing 42-, 43-pin, Hybrid System MQS/MPQ

Manufactured by AMP:  The following contact types without strand sealing can be fitted in the socket housings:

Open secondary locks (1) on socket housing.

Press back retaining hook of MQS contacts (2) with special tool 61 1 134 and pull out cable with contact.

Press back retaining hook of MPQ contacts (3) with screwdriver or similar tool and pull out cable with contact.

Fig 1: Pressing Back Retaining Hook Of MPQ Contacts With Screwdriver
G05478537Courtesy of BMW OF NORTH AMERICA, INC.

Installation: 

Bend open retaining hook of contacts gently before inserting into plug housing.

To install contacts, observe cavity numbers on reverse side of socket housing.

Fig 2: Identifying Cavity Numbers On Reverse Side Of Socket Housing
G05478538Courtesy of BMW OF NORTH AMERICA, INC.