Airflow Sensor
- To remove, disconnect airflow sensor connector. Unsnap finger clip and remove air cleaner cover. Remove filler from air cleaner body. Remove airflow sensor.
- To inspect, check air cleaner element, case and cover for damage and contamination. Replace if necessary. Perform ECI INSPECTION TEST. Check intake air temperature sensor by measuring resistance.AIRFLOW SENSOR (AFS) RESISTANCE
Temperature °F (°C) Resistance (Ohms) 68 (20) 2500 - To install, reverse removal procedure making sure airflow sensor connector is securely connected.