Intermittent Simulation
To reproduce the conditions creating an intermittent fault, use the following methods:
- Lightly vibrate or tap component.
- Heat component.
- Wiggle or bend wiring harness, shake, wiggle harness connector.
- Spray component with water.
- Remove/apply vacuum source.