SERVICE SPECIFICATIONS

Items Standard Value Limit
Generator
Regulated Voltage (Ambient temperature at voltage regulator) -20°C (-4°F) 14.2-15.4 -
20°C (68°F) 13.9-14.9 -
60°C (140°F) 13.4-14.5 -
80°C (176°F) 13.1-14.5 -
Generator output line voltage drop (at 30 A) V - Maximum 0.3
Output current - 70% of normal output
Field coil resistance ohm Approximately 2-5 -
Brush protrusion lingth mm (in) - Minimum 2 (0.08)