INSPECTION PROCEDURE E-1: Keyless Entry System: Keyless entry system does not operate.: Diagnosis
Required Special Tools:
- MB991223: Harness Set
- MB992006: Extra Fine Probe
- MB991958: Scan Tool (M.U.T.-III Sub Assembly)
- MB991824: V.C.I.
- MB991827: M.U.T.-III USB Cable
- MB991911: M.U.T.-III Main Harness B
- STEP 1. Verify the central door locking system.
Q: Does the central door locking system work normally?
YES: Go to Step 2.
NO: Refer to INSPECTION PROCEDURE C-1 "THE CENTRAL DOOR LOCKING SYSTEM DOES NOT WORK AT ALL ."
- STEP 2. Check the input signal (by using the Pulse check mode of the monitor).
Check input signals from the transmitter.
CAUTION: To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991958.- Connect scan tool MB991958 to the data link connector. Refer to "HOW TO CONNECT SWS MONITOR ."
- Operate scan tool MB991958 as follows:
- Select "Interactive Diagnosis."
- Select "System select."
- Select "SWS."
- Select "Pulse Checking."
- Push the transmitter "LOCK" or "UNLOCK" button.
- Check that scan tool MB991958 sounds.
Q: When the transmitter "LOCK" or "UNLOCK" button is turned ON, does scan tool MB991958 sound?
YES: Replace the ETACS-ECU. All the doors can be locked or unlocked by means of the transmitter.
NO: Refer to INSPECTION PROCEDURE O-9 "THE ETACS-ECU DOES NOT RECEIVE ANY SIGNAL FROM THE LOCK OR UNLOCK SWITCH ."