LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Nissan-Datsun >> 2011 >> Cube Base >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System - DTC U0101 Through DTC P0172 (For CALIFORNIA) >> DTC P0130: A/F Sensor 1 >> Diagnosis Procedure
September 30: LEMON manuals is back up on a temporary server! Slowness is possible

Diagnosis Procedure

  1. CHECK GROUND CONNECTION
    1. Turn ignition switch OFF.
    2. Check ground connection E38. Refer to "CIRCUIT INSPECTION ".

      Is the inspection result normal? 

      YES: Go to 2.

      NO: Repair or replace ground connection.

  2. CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
    1. Disconnect A/F sensor 1 harness connector.
    2. Turn ignition switch ON.
    3. Check the voltage between A/F sensor 1 harness connector and ground.
      VOLTAGE REFERENCE CHART

      A/F sensor 1 Ground Voltage
      Connector Terminal
      F51 4 Ground Battery voltage

      Is the inspection result normal? 

      YES: Go to  4.

      NO: Go to 3.

  3. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors E8, F1
    • IPDM E/R harness connector E15
    • 15 A fuse (No. 61)
    • Harness for open or short between A/F sensor 1 and fuse

      Repair or replace harness or connectors.

  4. CHECK A/F SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between A/F sensor 1 harness connector and ECM harness connector.
      CONTINUITY CHART

      A/F sensor 1 ECM Continuity
      Connector Terminal Connector Terminal
      F51 1 F8 49 Existed
      2 53
    4. Check the continuity between A/F sensor 1 harness connector and ground, or ECM harness connector and ground.
      CONTINUITY CHART

      A/F sensor 1 Ground Continuity
      Connector Terminal
      F51 1 Ground Not existed
      2
      CONTINUITY CHART

      ECM Ground Continuity
      Connector Terminal
      F8 49 Ground Not existed
      53
    5. Also check harness for short to power.

      Is the inspection result normal? 

      YES: Go to 5.

      NO: Repair open circuit or short to ground or short to power in harness or connectors.

  5. CHECK INTERMITTENT INCIDENT

    Perform "INTERMITTENT INCIDENT ".

    Is the inspection result normal? 

    YES: Go to 6.

    NO: Repair or replace.

  6. REPLACE AIR FUEL RATIO (A/F) SENSOR 1

    Replace air fuel ratio (A/F) sensor 1. Refer to "EXPLODED VIEW ".

    CAUTION:
    • Discard any sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
    • Before installing new sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J-43897-18 or J43897-12)] and approved Anti-seize Lubricant (commercial service tool).

    INSPECTION END