Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E38. Refer to
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES: Go to 2.
NO: Repair or replace ground connection.
- CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
- Disconnect A/F sensor 1 harness connector.
- Turn ignition switch ON.
- Check the voltage between A/F sensor 1 harness connector and ground.VOLTAGE REFERENCE CHART
A/F sensor 1 Ground Voltage Connector Terminal F51 4 Ground Battery voltage Is the inspection result normal?
YES: Go to 4.
NO: Go to 3.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E8, F1
- IPDM E/R harness connector E15
- 15 A fuse (No. 61)
- Harness for open or short between A/F sensor 1 and fuse
Repair or replace harness or connectors.
- CHECK A/F SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between A/F sensor 1 harness connector and ECM harness connector.CONTINUITY CHART
A/F sensor 1 ECM Continuity Connector Terminal Connector Terminal F51 1 F8 49 Existed 2 53 - Check the continuity between A/F sensor 1 harness connector and ground, or ECM harness connector and ground.CONTINUITY CHART
A/F sensor 1 Ground Continuity Connector Terminal F51 1 Ground Not existed 2 CONTINUITY CHARTECM Ground Continuity Connector Terminal F8 49 Ground Not existed 53 - Also check harness for short to power.
Is the inspection result normal?
YES: Go to 5.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK INTERMITTENT INCIDENT
Perform "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Go to 6.
NO: Repair or replace.
- REPLACE AIR FUEL RATIO (A/F) SENSOR 1
Replace air fuel ratio (A/F) sensor 1. Refer to "EXPLODED VIEW ".
CAUTION:- Discard any sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J-43897-18 or J43897-12)] and approved Anti-seize Lubricant (commercial service tool).
INSPECTION END