DTC Logic
DTC DETECTION LOGIC
| DTC No. | Trouble diagnosis name | DTC detecting condition | Possible cause |
|---|---|---|---|
| P2004 | Tumble control valve stuck | The target angle of tumble control valve controlled by ECM and the input signal from tumble control valve position sensor is not in the normal range. |
|
DTC CONFIRMATION PROCEDURE
- PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following before conducting the next test.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
- Before performing the following procedure, confirm that battery voltage is more than 11 V at idle .
- Always perform the test at a temperature above 0°C (32°F)
Go to 2.
- PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT-III
- Turn ignition switch ON.
- Select "DATA MONITOR" mode with CONSULT-III.
- Check that "COOLAN TEMP/S" indicates between 5°C (41°F) to 56°C (133°F). If not, cool engine down or warm engine up until "COOLAN TEMP/S" indicates between 5°C (41°F) to 56°C (133°F). Then go to the following steps.
- Fully release accelerator pedal and wait at least 5 seconds.
- Depress accelerator pedal and wait at least 5 seconds.
- Check 1st trip DTC.
With GST
Following the procedure "With CONSULT-III" above.
Is 1st trip DTC detected?
YES: Go to "DIAGNOSIS PROCEDURE ".
NO: INSPECTION END