Abs Solenoid Valve (Act)
- Select "Up", "ACT UP" and "ACT KEEP" of "ACTIVE TEST" in "ABS" with CONSULT. Then use screen monitor to check that solenoid valve operates as shown in the table below.
| Test item |
Display item |
Display (Note) |
| Up |
ACT UP |
ACT KEEP |
| FR RH ABS SOLENOID (ACT) |
FR RH IN SOL |
Off |
Off |
Off |
| FR RH OUT SOL |
Off |
Off |
Off |
| CV2 |
Off |
On |
On |
| SV2 |
Off |
On |
Off |
| FR LH ABS SOLENOID (ACT) |
FR LH IN SOL |
Off |
Off |
Off |
| FR LH OUT SOL |
Off |
Off |
Off |
| CV1 |
Off |
On |
On |
| SV1 |
Off |
On |
Off |
| RR RH ABS SOLENOID (ACT) |
RR RH IN SOL |
Off |
Off |
Off |
| RR RH OUT SOL |
Off |
Off |
Off |
| CV1 |
Off |
On |
On |
| SV1 |
Off |
On |
Off |
| RR LH ABS SOLENOID (ACT) |
RR LH IN SOL |
Off |
Off |
Off |
| RR LH OUT SOL |
Off |
Off |
Off |
| CV2 |
Off |
On |
On |
| SV2 |
Off |
On |
Off |
NOTE:
A brief moment of On/Off condition occurs every 20 seconds after ignition switch turned ON. This is not malfunction because it is an operation for checking.