Code P0134, Heated Oxygen Sensor Open Circuit: Notes
Control module supplies and monitors voltage of about .45 volt between control module HO2S low reference circuit and HO2S signal circuit. If read with a 10 megohm DVOM, voltage may read as low as .32 volt. HO2S varies voltage within a range of about 1 volt (rich) to .10 volt (lean). Sensor is like an open circuit and produces no voltage when less than about 600°F (360°C). Open loop operation is caused by open oxygen sensor circuit or a cold sensor. Code P0134 will cause system to operate in open loop. Control module will illuminate Malfunction Indicator Light (MIL).
NOTE:
Test numbers refer to numbers on diagnostic chart.
- If conditions necessary to set Code P0132 exist, system will not go into closed loop.
- This will determine if sensor or wiring is cause of Code P0134.