Code P1530, A/C Head Pressure Switch: Notes
A/C head pressure switch opens at 200-220 psi. When head pressure switch interrupts ground at control module, left fan should run at high speed. If Code P1530 is set, cooling fan(s) will run at high speed anytime A/C is requested. Code P1530 does not illuminate Malfunction Indicator Light (MIL).