Pull-In Windings Test
Connect test equipment as in hold-in windings test. See HOLD-IN WINDINGS TEST. See Fig 1 Ground starter solenoid terminal "M". Turn switch on and quickly adjust carbon pile load until voltage reads as specified. See PULL-IN WINDINGS SPECIFICATIONS table. Check ammeter reading. Turn off carbon pile and open switch. See PULL-IN WINDINGS SPECIFICATIONS table. If ammeter reading is not as specified, replace starter solenoid.
HOLD-IN WINDINGS SPECIFICATIONS
| Engine |
Starter Motor |
Amps |
| 3.1L |
PG260F |
6-12 |
| 3.8L |
| F2 |
PG260 F2 |
6-12 |
| M |
PG260 M |
6-12 |
PULL-IN WINDINGS SPECIFICATIONS
| Engine |
Starter Motor |
Amps |
| 3.1L |
PG260F |
30-45 |
| 3.8L |
| F2 |
PG260 F2 |
30-45 |
| M |
PG260 M |
30-45 |
Courtesy of GENERAL MOTORS CORP.