Pull-In Windings Test

Connect test equipment as in hold-in windings test. See HOLD-IN WINDINGS TEST. See Fig 1 . Ground starter solenoid terminal "M". Turn switch on and quickly adjust carbon pile load until voltage reads as specified. See the PULL-IN WINDINGS SPECIFICATIONS  table. Check ammeter reading. Turn off carbon pile and open switch. Refer to the PULL-IN WINDINGS SPECIFICATIONS  table. If ammeter reading is not as specified, replace starter solenoid.

HOLD-IN WINDINGS SPECIFICATIONS

Engine Starter Motor Amps
3.8L SD255 (1) 10-20
(1) At 10 volts.
PULL-IN WINDINGS SPECIFICATIONS

Engine Starter Motor Amps
3.8L SD255 (1) 60-85
(1) At 10 volts.
Fig 1: Solenoid Winding Test Connections