Test Description
The number below refers to the step number in the diagnostic procedures.
- 2 - This step verifies that the condition is present.
- 4 - This step tests the 5-volt reference of the FTP sensor.
- 5 - This step tests if another component is causing the 5-volt reference circuit condition.
- 6 - If scan tool displays 5 volts, the FTP sensor signal circuit, FTP sensor 5-volt reference circuit, and control module are okay.