LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Plymouth >> 1978 >> Arrow Base, Automatic Trans >> Repair and Diagnosis >> Electrical >> Starter >> Starters >> Testing >> Locked Resistance Test
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Locked Resistance Test

Mount starter in test bench. Follow test equipment manufacturers instructions. With battery voltage adjusted to 4 volts, amperage draw should be as shown in specifications.

STARTER SPECIFICATIONS

Application Amps.
Cranking Amperage Test  
  Model No. 3755900 (1.5 HP) 165-180
  Model No. 3755250 (1.8 HP) 180-200
Solenoid Amperage Test (6 volts @ 77°F)  
  Pull-In Circuit 13-15
  Hold-In Circuit 8-9
No Load Amperage Test  
  Model No. 3755900 (3700 RPM minimum) 90
  Model No. 3755250 (5700 RPM minimum) 90
Lock Resistance Amperage Test 475-550