Coolant Vacuum Switch
- Disconnect molded connector from valve and attach a 1/8" I-D. hose to bottom port of valve. With radiator top tank warm to touch (no warmer than 75°F), blow through hose. If air cannot be blown through valve, replace valve.
- Bring engine to normal operating temperature. Attach a vacuum pump and gauge to bottom port of valve. Apply ten inches of vacuum. If vacuum level drops more than one inch in 15 seconds, replace valve.
Courtesy of CHRYSLER GROUP, LLC