Rectifier Assembly Check
Using an ohmmeter, check for continuity between positive heat sink and stator coil lead connection terminal. Reverse ohmmeter leads. If continuity exists in both directions, diode is shorted. Replace rectifier assembly. Attach ohmmeter leads to negative heat sink and stator coil lead connection terminal. Again, continuity should only exist in one direction.