Airflow Sensor Test
- To remove, disconnect airflow sensor connector. Unsnap finger clip and remove air cleaner cover. Remove filler from air cleaner body. Remove airflow sensor.
- To inspect, check air cleaner element, case and cover for damage and contamination. Replace if necessary. Perform ECI INSPECTION TEST. Check intake air temperature sensor by measuring resistance.
- To install, reverse removal procedure making sure airflow sensor connector is securely connected.
AIRFLOW SENSOR (AFS) RESISTANCE
| Temperature °F (°C) | Resistance (Ohms) |
|---|---|
| 68 (20) | 2500 |