Functional Test
NOTE:
Perform tests in order shown. Allow time between steps for programmer to function and system to stabilize.
- Set Selector Lever at OFF and Temperature Dial to MAX HEAT.
- Blower runs at low speed, warm air from heater outlet only.
- Assures of: Low blower, sealed defroster, open water control valve, compressor not running.
- Move Selector Lever to VENT.
- Blower speed remains low, cool air from A/C outlets.
- Assures of: Low blower, A/C mode, minimum temperature, closed water valve, compressor not running.
- Move Selector Lever to LO.
- Blower remains at low and airflow is from heater outlet or heater and A/C outlets (depending on ambient temperature). Air temperature slightly increased from that in step 2).
- Assures of: Low blower, mode control, temperature control, compressor running.
- Move Temperature Dial to MAX COLD.
- Blower remains at low and air flow is from A/C outlet or A/C and heater outlets. Air temperature is lower than in step 3).
- Assures of: Low blower, mode control control, compressor is running.
- Move Selector Lever to AUTO.
- Blower speed increases. Airflow and temperature same as in step 4).
- Assures of: Blower control, temperature control, mode control, compressor is running.
- Move Temperature Dial to MAX HEAT.
- Blower speed decreases, then increases while Temperature Dial is being moved. Air flow from heater outlet or heater and A/C outlets at increased temperature from step 5).
- Assures of: Blower control, mode control, temperature control, compressor is running.
- Move Selector Lever to HI.
- Blower speed increases to high. Airflow and temperature remain same as in step 6).
- Assures of: High blower, mode control, temperature control, compressor is running.
- Move Selector Lever to DEFOG.
- Blower speed decreases slightly. Airflow is from heater and A/C outlets (bi-level). Temperature remains warm.
- Assures of: Bi-level mode, blower control, temperature control, compressor is running.
- Move Temperature Dial to MAX COLD.
- Blower speed decreases, then increases while Dial is being moved. Air temperature decreases, airflow remains bi-level.
- Assures of: Bi-level mode, blower control, compressor is running.
- Move Selector Lever to DEICE.
- Blower speed same as in step 7). Airflow remains cool and is from defroster nozzles.
- Assures of: High blower, DEICE mode, temperature control, compressor is running.
- Move Temperature Dial to MAX HEAT.
- Blower speed and air flow same as step 10), air temperature increases.
- Assures of: High blower, DEICE mode, temperature control, compressor is running.