Installation Procedure
- Clean the sealing surface of the BPMV, with denatured alcohol and a clean shop cloth.
- If the EBCM that was removed is being reinstalled, clean the seal and sealing surface of the EBCM, with denatured alcohol and a clean shop cloth.
- Install the EBCM (1) to the BPMV (2). Use care when aligning the EBCM to the BPMV electrical terminals.NOTE: Refer to Fastener Notice in Cautions and Notices.
- Install the 4 EBCM-to-BPMV retaining bolts. Tighten the bolts in a criss-cross pattern.
Tighten: Tighten the bolts to 5 N.m (44 lb in).
- Connect the electrical harness connector (4) to the EBCM (3).
- Depress the cover lock tab, then move the sliding connector cover (2) to the home position to lock.
- Engage the electrical connector CPA locking tab (1) to the connector sliding cover lock tab.
- Perform the ABS Diagnostic System Check. Refer to Diagnostic System Check - ABS .