Scan Tool Output Controls
Scan Tool Output Controls
| Scan Tool Output Control | Additional Menu Selection(s) | Description |
|---|---|---|
| Automated Bleed Procedure | - | Used in order to bleed the ABS hydraulics. Refer to ABS Automated Bleed Procedure . |
| ABS Telltale Indicator | Lamp and Gauge Check | Commands the ABS indicator ON and OFF |
| LF Inlet Valve Solenoid | Solenoid Test | Commands the solenoid ON and OFF |
| LF Outlet Valve Solenoid | Solenoid Test | Commands the solenoid ON and OFF |
| Pump Motor Test | - | Commands the pump motor ON and OFF |
| RF Inlet Valve Solenoid | Solenoid Test | Commands the solenoid ON and OFF |
| RF Outlet Valve Solenoid | Solenoid Test | Commands the solenoid ON and OFF |
| LR Inlet Valve Solenoid | Solenoid Test | Commands the solenoid ON and OFF |
| LR Outlet Valve Solenoid | Solenoid Test | Commands the solenoid ON and OFF |
| RR Inlet Valve Solenoid | Solenoid Test | Commands the solenoid ON and OFF |
| RR Outlet Valve Solenoid | Solenoid Test | Commands the solenoid ON and OFF |