LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Pontiac >> 2009 >> G3 Automatic >> Repair and Diagnosis >> Brakes >> Traction Control >> Antilock Brake System >> Diagnostic Information and Procedures >> No Communication with Electronic Brake Control Module >> Circuit/System Testing
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Circuit/System Testing

  1. Ignition OFF, disconnect the EBCM connector.
  2. Ignition ON, check for 11-14V between the B+ circuit and ground.
    • If the voltage is not as specified, test the B+ circuit for a short to ground or an open/high resistance.
  3. Test for less than 1 ohm between the ground circuits and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance. If the circuit tests normal, replace the BPMV/EBCM.