Blower Motor

Fig 1: Blower Motor Connector End View
GM1467007Courtesy of GENERAL MOTORS CORP.
Blower Motor

Pin Wire Circuit Function
1 D-BU/RD - Blower Motor Control
2 RD/WH - Blower Motor Supply Voltage
Connector Part Information 
  • OEM: MG610043
  • Service: N/A
  • Description: 2-Way F 250 Series (WH)


-

Connector Part Information 
  • OEM:
  • Service: N/A
  • Description:
Blower Motor

Pin Wire Circuit Function
1 BK - Ground
2 RD/BK - Battery Positive Voltage