Diagnostic Fault Information

WARNING: This page is about a different car, the 2008 Pontiac G5 and 2008 Chevrolet Cobalt. However, it is still accessible from the selected car via links, so may be relevant.
Circuit Short to Ground Open/High Resistance Short to Voltage Signal Performance
Class 2 Serial Data 1 1 1 -
Ground (DLC, terminal 5) - 1 - -
1. A short voltage, short to ground, or an open between the data link connector (DLC) and the PCM, or an open between the DLC terminal 5 and ground will only effect the communication with the scan tool. The PCM will still communicate on HS GMLAN.