Vehicle Direction Alert Alarm Warning Module Scan Tool Information

WARNING: This page is about a different car, the 2008 Cadillac DTS. However, it is still accessible from the selected car via links, so may be relevant.
Veh Direction Alert Alarm Warn Module Scan Tool Parameters

Parameter System State Expected Value Definition
Operating Conditions:  Ignition ON
Battery Voltage - Varies The scan tool displays volts. This is the current battery voltage.
Calibration Status - Inactive The scan tool displays Active or Inactive. Active is displayed when the VDAAW calibration is in progress.
Calibration Status - Inhibit The scan tool displays Inhibit or OK. Inhibit is displayed when the VDAAW detects a fault in the calibration status.
Diagnostic Mode - Inhibit The scan tool displays Inhibit or OK. Inhibit is displayed when the VDAAW detects a fault in the diagnostic mode.
Mode LED - OFF The scan tool displays Off or On. On is displayed when the VDAAW mode LED is illuminated.
Mode Switch - Inactive The scan tool displays Active or Inactive. This is the status of the VDAAW mode switch
Operating State - OFF The scan tool displays Off, Disabled, Not Ready, and Ready. This is the operating state of the VDAAW module.
Power Mode - OFF The scan tool displays Off, Run, Crank Request, and Accessory. This is the state of power for the VDAAW module.
Power Mode - Inhibit The scan tool displays Inhibit or OK. Inhibited is displayed when VDAAW detects a fault in the power mode.
Reference Voltage 1 - Varies The scan tool displays volts.
Reference Voltage 2 - Varies The scan tool displays volts.
Serial Data - Inhibit The scan tool displays Inhibit or OK. Inhibit is displayed when VDAAW detects a fault in the serial data.
System Operation Status - Unknown The scan tool displays Unknown, Normal, Disabled, and Failed. This is the status of the VDAAW modules system operation.
System Power Mode - Inhibit The scan tool displays Inhibit or OK. Inhibit is displayed when the VDAAW detects a fault in the system power mode.
Veh Direction Alert Alarm Warn Module Scan Tool Output Controls

Scan Tool Output Control Description
Calibrate Module This output control is used to calibrate the VDDAW module.
Direction Warning Left This output control is used to calibrate the left sensor.
Direction Warning Right This output control is used to calibrate the right sensor.