LNF Engine
- Verify that a test lamp illuminates between the generator B+ terminal A X2 and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
- Ignition OFF, disconnect the harness connector X1 at the generator.
- Ignition ON, test for less than 1 V between the generator turn on signal circuit terminal B X1 and ground.
- If greater than the specified range, test the generator turn on signal circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Engine running, test for greater than 3.5 V between the generator turn on signal circuit terminal B and ground.
- If less than the specified range, test the generator turn on signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If the circuit tests normal, test or replace the generator.