Temperature Sensor II

Remove CU connector plug. Connect a ohmmeter between terminal No. 13 and ground. Compare ohmmeter readings to specifications.

TEMPERATURE SENSOR II SPECIFICATIONS

Temperature Ohms +/-10%
50°F (10°C) 3300-4100
68°F (20°C) 2200-2800
104°F (40°C) 1000-1300
176°F (80°C) 290-350
212°F (100°C) 160-210