Coding Level Control Module
Information
- During coding, it is essential to guarantee the power supply for the PIWIS Tester 9718. It is essential to connect a battery charger with a current rating of at least 40 A to the vehicle battery.
- The PIWIS Tester 9718 instructions take precedence and in the event of a discrepancy these are the instructions that must be followed. Deviations may occur with later software versions.
- The procedure described here has been structured in general terms; different text or additions may appear in the PIWIS tester 9718 .
- Connect the PIWIS tester 9718 to the vehicle and start it. Switch on the ignition. [>>] Continue.
- Select vehicle type using the cursor keys.
- Using the [>>] key, move from the vehicle type to the list of control modules.
- Select Level control and press the [>>].
- Select Coding and press the [>>].
- Select Select country and code with the F8.
Select country Cayenne RoW Cayenne Thailand - Read out fault memory and erase if required.