Symptom In Vehicle Interior - Air-Conditioning System Does Not Function: Re-Programming Air-Conditioning Control Unit (SY 27/15) (GROUP 8, NO. 27/15)
Publication date: 2017-02-17Reference number: GROUP 8, NO. 27/15
SYMPTOM IN VEHICLE INTERIOR - AIR-CONDITIONING SYSTEM DOES NOT FUNCTION: RE-PROGRAMMING AIR-CONDITIONING CONTROL UNIT (SY 27/15)
TECHNICAL SERVICE BULLETIN
| PORSCHE: | Macan as of 2015 |
SERVICE INFORMATION
Dr. Ing. h.c. F. Porsche AG is the owner of numerous trademarks, both registered and unregistered, including without limitation the Porsche Crest®, Porsche®, Boxster®, Carrera®, Cayenne®, Cayman®, Macan®, Panamera®, Speedster®, Spyder®, Tiptronic®, VarioCam®, PCM®, PDK®, 911®, RS®, 4S®, 718®, 918 Spyder®, FOUR UNCOMPROMISED®, and the model numbers and distinctive shapes of the Porsche automobiles such as, the federally registered 911 and Boxster automobiles. The third party trademarks contained herein are the properties of their respective owners. Porsche Cars North America, Inc. believes the specifications to be correct at the time of printing. However, specifications, standard equipment and options are subject to change without notice. Some options may be unavailable when a car is built. Some vehicles may be shown with non-U.S. equipment. Please ask your authorized Porsche dealer for advice concerning the current availability of options and verify the optional equipment that you ordered. Porsche recommends seat belt usage and observance of traffic laws at all times
TOOLS
| Designation | Type | Number | Description | |
|---|---|---|---|---|
| PIWIS Tester III | Special tool | 9900 |
MODEL YEAR
as of 2015
General information
MODEL LINE
Macan
SYMPTOM
No cooling performance from the air-conditioning system.
CAUSE
The evaporator for the air-conditioning system can freeze at high outside temperatures and high humidity.
REMEDIAL ACTION
Re-program control unit for air-conditioning system using a modified parameter set.
Information
Before doing any other work, the software version must be read out of the air-conditioning control unit using the PIWIS Tester.
=> If the software version is higher than "1040", the remedial action described below must not be carried out.
=> The software in the air-conditioning control unit is already the latest version in this case. Programming the air-conditioning control unit using the programming code will not resolve the problem.
TOOLS
Battery Charger/Power Supply - Suitable for AGM Type batteries, recommended current rating of 70A fixed voltage 13.5V to 14.5V.
PIWIS Tester III 9900
RE-PROGRAMMING AIR-CONDITIONING CONTROL UNIT
Preliminary work:
- Increased current draw during diagnosis or control unit programming can cause a drop in voltage, which can result in one or more fault entries and the abnormal termination of the programming process.
→ Before starting control unit programming, connect a suitable battery charger or power supply, suitable for AGM type batteries, recommended current rating of 70A fixed voltage 13.5V to 14.5V.
- An unstable WLAN connection can interrupt communication between PIWIS Tester III and the vehicle communication module (VCI). As a result, control unit programming may be aborted.
→ During control unit programming, always connect PIWIS Tester II to the vehicle communication module (VCI) via the USB cable.
- If the driver's key is not recognized in vehicles with Porsche Entry & Drive, programming cannot be started or will be interrupted.
→ Switch on the ignition using the original driver's key. To do this, replace the control unit in the ignition lock with the original driver's key if necessary.
- Carry out general preliminary work for control unit programming as described in → 9X00IN Basic instructions and procedure for control unit programming using the PIWIS Tester - section on "Preliminary work".
Information
Before doing any other work, the software version must be read out of the air-conditioning control unit using the PIWIS Tester.
=> If the software version is higher than "1040", the remedial action described below must not be carried out.
=> The software in the air-conditioning control unit is already the latest version in this case. Programming the air-conditioning control unit using the programming code will not resolve the problem.
Re-program control unit for air-conditioning system.
The basic procedure for programming a control unit is described in the Workshop Manual → 9X00IN Basic instructions and procedure for control unit programming using the PIWIS Tester - section on "Programming".
Specific information on control unit programming during this repair measure:
SOFTWARE INFORMATIONReading out the software version: 'Air-conditioning' control unit => 'Extended identifications' menu
=> Software version:- The measure described below must only be carried out if the software version is lower than 1040.
Required PIWIS Tester III software version: 33.800.020 (or higher) Type of control unit programming: Control unit programming using the "Campaign" function in the Additional menu on the PIWIS Tester by entering a programming code. Programming code: R4K5P Programming sequence: Read and follow the information and instructions on the PIWIS Tester during the guided programming sequence. The control unit for the air-conditioning system is reprogrammed first during the programming sequence. Once programming is complete, the control unit is re-coded automatically.
Do not interrupt programming and coding.Time required for programming and coding: approx. 4 minutes Software version programmed during this repair measure: 1040 Following control unit programming, the software version can be read out of the air-conditioning system control unit in the → 'Extended identification' menu using the PIWIS Tester. Procedure in the event of error messages appearing during the programming sequence: → 9X00IN Basic instructions and procedure for control unit programming using the PIWIS Tester - section on "Fault finding". Procedure in the event of abnormal termination of control unit programming: Repeat control unit programming by entering the programming code again. Subsequent work:
- Carry out general subsequent work for control unit programming as described in the Workshop Manual → 9X00IN Basic instructions and procedure for control unit programming using the PIWIS Tester - section on "Subsequent work".
INVOICING
The work involved is invoiced under the labor operation:
| 87022580 | Programming air conditioning control | - - |
For invoicing and documentation using PQIS, enter the following coding:
| 87020 | Air conditioning control | |
| 9830 | Cannot establish cause, software re-installed |
References:
→ 9X00IN Basic instructions and procedure for control unit programming using the PIWIS Tester - section on "Preliminary work"
→ 9X00IN Basic instructions and procedure for control unit programming using the PIWIS Tester - section on "Subsequent work"
95BAA1, 95BAB1, 95BAD1, 95BAF1, 95BAJ1, 95BAK1, 95BAZ1
Model year as of 2015
C02, C36