Installing Control Unit For Distance Measuring Sensor
Information
Before and after installing the trim cover for the distance measuring sensor control unit, check the following points:
- The distance measuring sensor control unit holder must not be deformed. If it is, carefully push the distance measuring sensor control unit holder back into shape.
- If the trim cover is damaged or cracked, replace the trim cover.
- After installing the trim cover, check that it is seated correctly and securely.
- Installation is performed in reverse order.
- Screw in and tighten nuts on control unit for distance measuring sensor. > Tightening torque 9 Nm (6.5 ftlb.)