Idle Adjustment
Engine must be at normal operating temperature.
- Attach tachometer and suitable exhaust gas analyzer. Set idle adjustment to 900 RPM with headlights on and in low beam position.
- Adjust mixture control screw to obtain a reading of 2.0±.25% CO. Turn screw clockwise to obtain a lower CO content and counterclockwise to increase CO. Recheck idle speed and adjust if necessary.