Preparation For Checks
- Frequency valve is operated by pulsating voltage from ECU. By measuring this signal, mixture function of system can be tested and changed. A high-quality dwell meter is used to check and adjust frequency valve control and duty cycle.
- Connect tachometer and oil temperature gauge. Ensure A/C is off and transmission lever is in Park. Throttle valve lever must be against idle stop. Accelerator Bowden cable must be tension free at throttle lever. Adjust if necessary.
- Engine oil must be at operating temperature of 176°F (80°C). Check and adjust idle speed if necessary. Connect a dwell meter to 2-wire testing connector.
- The color-coded wire should be connected to positive (+) lead of dwell meter. Other wire in connector is ground and should be connected to negative (-) lead of dwell meter. Set the dwell meter on 4-cylinder scale. Start engine and run until warm.