Circuit/System Testing
- Ignition ON, verify that the IPC warning indicators are illuminated.
- If the IPC warning indicators are not illuminated, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition circuit fuse is open, replace the IPC.
- Ignition OFF, disconnect ECM X1 harness connector. Ignition ON, the MIL should not illuminate.
- If the MIL is illuminated, test the MIL control circuit terminal listed below for a short to ground. If the circuit tests normal, replace the IPC.
- ECM terminal X1-27 for RPO LE5
- ECM terminal X1-12 for RPO LAT
- Ignition ON, connect a 3A fused jumper wire between the MIL control circuit terminal listed below and ground. The MIL should illuminate.
- ECM terminal X1-27 for RPO LE5
- ECM terminal X1-12 for RPO LAT
- If the MIL does not illuminate, test the MIL control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the IPC/bulb.
- If all circuits/connections test normal, replace the ECM.