LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Saturn >> 2002 >> SL >> Repair and Diagnosis >> Electrical >> Charging Systems >> Description & Operation
September 30: LEMON manuals is back up on a temporary server! Slowness is possible

Description & Operation

The battery supplies voltage to the generator at all times. During engine start-up, the Instrument Panel (I/P) cluster performs a bulb check by illuminating Charge telltale for 3 seconds. The PCM supplies 5 volts to the generator L-terminal to initiate charging. The system charges the battery and provides power to the vehicle electrical devices. The PCM can increase idle speed to boost generator output if the battery voltage drops below specification. If the charging circuit malfunctions, the PCM signals the I/P cluster to illuminate the Charge telltale.