Typical Scan Tool Data

ECT Sensor Temperature

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Engine Operating in Closed Loop
Parameter Normal Range:  Varies wit coolant temperature
ECT Sensor Signal 150°C (303°F) -40°C (-40°F) -40°C (-40°F)*
Low Reference - -40°C (-40°F) -40°C (-40°F)*
*ECM or sensor damage may occur if the circuit is shorted to B+