Typical Scan Tool Data
CMP Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine Running Parameter Normal Range: 400-6400 RPM. CMP Sensor parameter should match engine speed parameter. |
|||
| 5-Volt Reference Circuit | 0 RPM | 0 RPM | 0 RPM |
| CKP Sensor Signal Circuit | 0 RPM | 0 RPM | 0 RPM |
| Low Reference Circuit | Same as Engine Speed | 0 RPM | 0 RPM |