Charging System Operation: Notes

WARNING: This page is about a different car, the 2007 Pontiac Montana SV6, 2007 Chevrolet Uplander, and 2007 Buick Terraza. However, it is still accessible from the selected car via links, so may be relevant.

The purpose of the charging system is to maintain the battery charge and vehicle loads. There are 6 modes of operation and they include:

The engine control module (ECM) controls the generator through the generator field control circuit. It monitors the generator performance through the generator field duty cycle signal circuit. The signal is a pulse width modulated (PWM) signal of 128 Hz with a duty cycle of 0-100 percent. Normal duty cycle is between 5-95 percent. Between 0-5 percent and 95-100 percent are for diagnostic purposes. The following table shows the commanded duty cycle and output voltage of the generator:

Charging System Description and Operation

Commanded Duty Cycle Generator Output Voltage
10% 11 V
20% 11.56 V
30% 12.12 V
40% 12.68 V
50% 13.25 V
60% 13.81 V
70% 14.37 V
80% 14.94 V
90% 15.5 V

The generator provides a feedback signal of the generator voltage output through the generator field duty cycle signal circuit to the PCM/ECM, this information is sent to the body control module (BCM). The signal is a PWM signal of 128 Hz with a duty cycle of 0-100 percent. Normal duty cycle is between 5-99 percent. Between 0-5 percent and 100 percent are for diagnostic purposes.