| 1 |
0.8 RD |
101 |
Battery Positive Voltage |
| 2 |
0.8 WH |
102 |
Inlet Air Temp sensor source |
| 3 |
0.8 GY |
103 |
Coolant Temp sensor source |
| 4-5 |
- |
- |
Not Used |
| 6 |
0.8 WH |
106 |
Battery Temp sensor 2 source |
| 7 |
0.35 BK |
107 |
Service CAN High |
| 8 |
0.35 YE |
108 |
High Speed GMLAN Serial Data Bus + |
| 9 |
0.35 WH |
109 |
High Speed GMLAN Serial Data Bus - |
| 10-12 |
- |
- |
Not Used |
| 13 |
0.35 RD |
101 |
Battery Positive Voltage |
| 14 |
- |
- |
Not Used |
| 15 |
0.8 WH/GN |
115 |
High Voltage Interlock Loop Signal (1) |
| 16 |
- |
- |
Not Used |
| 17 |
0.35 GN |
117 |
5 Volt + Current Sensor Supply |
| 18 |
0.8 YE |
118 |
Serial Data Communication Enable |
| 19 |
0.8 WH/YE |
119 |
Hybrid Accessory Input |
| 20-21 |
- |
- |
Not Used |
| 22 |
0.35 WH |
122 |
Battery Temp sensor 4 source |
| 23 |
0.35 WH |
123 |
Service CAN Low |
| 24 |
0.35 RD |
124 |
High Speed GMLAN Serial Data Bus + |
| 25 |
0.35 WH |
125 |
High Speed GMLAN Serial Data Bus - |
| 26-27 |
- |
- |
Not Used |
| 28 |
0.35 PU/WH |
128 |
Coolant Pump Signal |
| 29 |
- |
- |
Not Used |
| 30 |
0.35 BK |
130 |
Current Sensor Return |
| 31 |
- |
- |
Not Used |
| 32 |
0.35 WH |
132 |
Current Sensor Signal |
| 33 |
0.35 GY/BK |
133 |
Coolant Pump Control |
| 34-39 |
- |
- |
Not Used |
| 40 |
0.35 WH |
140 |
Battery Temp Sensor 3 Supply |
| 41 |
0.35 WH |
141 |
Battery Temp Sensor 1 Supply |
| 42 |
0.35 OG |
142 |
Battery Temp Sensor 3 Signal |
| 43 |
0.35 GY/WH |
143 |
Coolant Fan Signal (Tach) |
| 44 |
0.8 GY |
144 |
HV Battery Pack Contactor Control Signal |
| 45 |
0.35 BK |
145 |
Battery Temp Sensor 4 Signal |
| 46 |
0.35 BN |
146 |
Battery Temp Sensor 1 Signal |
| 47 |
0.8 WH/BK |
147 |
BPCM Ground |
| 48 |
0.35 BVK |
148 |
Cooling Fan and Pump Ground |
| 49 |
0.35 D-BU |
149 |
12 Volt Contactor Relay Coil Supply |
| 50 |
0.35 GN/WH |
150 |
Precharge Contactor Relay Control |
| 51 |
0.35 OG/WH |
151 |
Positive Contactor Relay Control |
| 52 |
0.35 GY |
152 |
Negative Contactor Relay Control |
| 53 |
- |
- |
Not Used |
| 54 |
0.35 WH |
154 |
Fan # 1 Control |
| 55-56 |
- |
- |
Not Used |
| 57 |
0.35 RD/WH |
157 |
12 Volt Pump Supply |
| 58-59 |
- |
- |
Not Used |
| 60 |
0.35 RD |
160 |
12 Volt Fan Supply |
| 61-64 |
- |
- |
Not Used |
| 65 |
0.35 BK |
165 |
Inlet Air Temp Sensor Signal |
| 66 |
0.35 WH |
166 |
Coolant Temp Sensor Signal |
| 67 |
0.8 BU |
167 |
BP Fan and Pump Power |
| 68 |
0.8 BU |
| 69 |
- |
- |
Not Used |
| 70 |
0.35 GN |
170 |
Battery Temp Sensor 2 Signal |
| 71 |
0.8 BN |
202 |
High Voltage Interlock Loop Signal (2) |
| 72 |
- |
- |
Not Used |
| 73 |
0.35 BK |
148 |
Cooling Fan and Pump Ground |