Hand-Held Tester:
- READ VALUE USING HAND-HELD TESTER (THROTTLE VALVE OPENING PERCENTAGE)
- Connect a hand-held tester or OBD II scan tool to the DLC3.
- Start the engine.
- Turn the tester or scan tool ON.
- On the tester, select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ETCS / THROTTLE POS.
- Read its value displayed on the tester when the accelerator pedal is released and depressed.
Result:
THROTTLE VALVE OPENING ANGLE POSITIONThrottle Valve Opening Angle (%) Proceed To 0 A From approximately 0 to 75 B Approximately 100 C
- B : (See CHECK FOR INTERMITTENT PROBLEMS )
- C : Go to step 4
- A : GO TO NEXT STEP
- INSPECT THROTTLE POSITION SENSOR
- Disconnect the T1 Throttle Position (TP) sensor connector.
- Measure the resistance between the terminals of the TP sensor.
Standard:
TESTER CONNECTIONS SPECIFICATIONSTester Connections Throttle Valve Positions Specified Conditions VC (T1-1) - E2 (T1-2) - Between 2.5 kΩ and 5.9 kΩ VTA (T1-3) - E2 (T1-2) Fully closed Between 0.2 kΩ and 5.7 kΩ VTA (T1-3) - E2 (T1-2) Fully open Between 2.0 kΩ and 10.2 kΩ - Reconnect the TP sensor connector.
- NG : REPLACE THROTTLE POSITION SENSOR
- OK : GO TO NEXT STEP
- CHECK HARNESS AND CONNECTOR (ECM - THROTTLE POSITION SENSOR)
- Disconnect the E3 ECM connector.
- Measure the resistance between the terminals of the E3 ECM connector.
Standard:
TESTER CONNECTIONS SPECIFICATIONSTester Connections Throttle Valve Positions Specified Conditions VCC (E3-18) - E2 (E3-28) - Between 2.5 kΩ and 5.9 kΩ VTA (E3-21) - E2 (E3-28) Fully closed Between 0.2 kΩ and 5.7 kΩ VTA (E3-21) - E2 (E3-28) Fully open Between 2.0 kΩ and 10.2 kΩ - Check the resistance between the terminals of the E3 ECM connector.
Standard (Check for short):
TESTER CONNECTIONS SPECIFICATIONSTester Connections Specified Conditions VCC (E3-18) - Body ground 10 kΩ or higher VTA (E3-28) - Body ground 10 kΩ or higher - Reconnect the ECM connector.
- NG : REPAIR OR REPLACE HARNESS OR CONNECTOR
- OK : REPLACE ECM (See REPLACEMENT )
- INSPECT THROTTLE POSITION SENSOR
- Disconnect the T1 TP sensor connector.
- Measure the resistance between the terminals of the TP sensor.
Standard:
TESTER CONNECTIONS SPECIFICATIONSTester Connections Throttle Valve Positions Specified Conditions VC (T1-1) - E2 (T1-2) - Between 2.5 kΩ and 5.9 kΩ VTA (T1-3) - E2 (T1-2) Fully closed Between 0.2 kΩ and 5.7 kΩ VTA (T1-3) - E2 (T1-2) Fully open Between 2.0 kΩ and 10.2 kΩ - Reconnect the TP sensor connector.
- NG : REPLACE THROTTLE POSITION SENSOR"
- OK : GO TO NEXT STEP
- CHECK HARNESS AND CONNECTOR (ECM - THROTTLE POSITION SENSOR)
- Disconnect the E3 ECM connector.
- Disconnect the T1 TP sensor connector.
- Check the resistance.
Standard (Check for open):
TESTER CONNECTIONS SPECIFICATIONSTester Connections Specified Conditions VC (T1-1) - VCC (E3-18) Below 1 Ω VTA (T1-3) - VTA (E3-21) Below 1 Ω E2 (T1-2) - E2 (E3-28) Below 1 Ω Standard (Check for short):
TESTER CONNECTIONS SPECIFICATIONSTester Connections Specified Conditions VC (T1-1) or VCC (E3-18) - Body ground 10 kΩ or higher VTA (T1-3) or VTA (E3-21) - Body ground 10 kΩ or higher - Reconnect the TP sensor connector.
- Reconnect the ECM connector.
- NG : REPAIR OR REPLACE HARNESS OR CONNECTOR
- OK : REPLACE ECM (See REPLACEMENT )