Monitor Strategy
| Related DTCs | P0101: Mass air flow meter rationality check |
| Required Sensors/Components (Main) | Mass air flow meter |
| Required Sensors/Components (Related) | Crankshaft position sensor VVT sensor Engine coolant temperature sensor Throttle position sensor |
| Frequency of Operation | Continuous |
| Duration | Low side: 5 seconds High side: 10 seconds |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |