How To Proceed With Troubleshooting [05/2013 - ]
HINT:
- Use these procedures to troubleshoot the power window control system.
- *: Use the Techstream.
- VEHICLE BROUGHT TO WORKSHOP
NEXT: Go to next step
- INSPECT BATTERY VOLTAGE
Standard voltage
11 to 14 V
If the voltage is below 11 V, recharge or replace the battery before proceeding.
NEXT: Go to next step
- CHECK FOR DTC*
- Check for DTCs and make a note of any codes that are output.
- Clear the DTCs.
- Recheck for DTCs. Based on the DTCs output in the first step, try to force output of the same DTC by simulating the symptoms indicated by the DTC.RESULT
Result Proceed to No DTCs output A DTCs output B LIN communication system DTCs are output C B → GO TO DIAGNOSIS TROUBLE CODE CHART. Refer to DIAGNOSTIC TROUBLE CODE CHART [05/2013 - ]
C → GO TO LIN COMMUNICATION SYSTEM. Refer to DIAGNOSTIC TROUBLE CODE CHART [05/2013 - ]
A: Go to next step
- PROBLEM SYMPTOMS TABLE
- Refer to the Problem Symptoms Table. Refer to PROBLEM SYMPTOMS TABLE [05/2013 - ] .RESULT
Result Proceed to Fault not listed in Problem Symptoms Table A Fault listed in Problem Symptoms Table B B → Go to step 6
A: Go to next step
- Refer to the Problem Symptoms Table. Refer to PROBLEM SYMPTOMS TABLE [05/2013 - ] .
- OVERALL ANALYSIS AND TROUBLESHOOTING*
- Operation Check. Refer to OPERATION CHECK [05/2013 - ] .
- Terminals of ECU. Refer to TERMINALS OF ECU [05/2013 - ] .
- Data List/Active Test. Refer to DATA LIST / ACTIVE TEST [05/2013 - ] .
NEXT: Go to next step
- REPAIR OR REPLACE RESULT
Result Proceed to Door window regulator and power window regulator motor assembly are replaced or removed/installed. A Door window regulator and power window regulator motor assembly are not replaced or removed/installed. B B → Go to step 8
A: Go to next step
- RESET POWER WINDOW REGULATOR MOTOR
- If the power window regulator master switch AUTO light is blinking, reset the power window regulator motor. Refer to INITIALIZATION [05/2013 - ] .
NEXT: Go to next step
- If the power window regulator master switch AUTO light is blinking, reset the power window regulator motor. Refer to INITIALIZATION [05/2013 - ] .
- CONFIRMATION TEST
NEXT → END