DTC B1796: Sleep Operation Failure of Occupant Classification ECU [06/2015 - ]: Procedure
- REPLACE OCCUPANT DETECTION ECU
- Turn the ignition switch off.
- Disconnect the cable from the negative (-) battery terminal.
- Replace the occupant detection ECU.
Refer to REMOVAL [06/2015 - ]
- Connect the cable to the negative (-) battery terminal.
Result
Proceed to NEXT
Result: 1
NEXT
See step 2
- PERFORM ZERO POINT CALIBRATION AND SENSITIVITY CHECK
- Using the Techstream, perform zero point calibration and sensitivity check.
Refer to INITIALIZATION [06/2015 - ]
Body Electrical > Occupant Detection > Utility
Tester Display Zero Point Calibration & Sensitivity Check Result
Proceed to NEXT
Result: 1
NEXT
END
- Using the Techstream, perform zero point calibration and sensitivity check.