Typical Enabling Conditions
ALL
| The monitor will run whenever the following DTCs are not present | None |
| Battery voltage | 10.5 V or more |
| Write Inhibit | permit |
| Time after Write status forbiddance to permit | 0.5 seconds or more |
| Ignition switch | ON |
| Time after Ignition switch OFF to ON | 0.5 seconds or more |
| Starter | OFF |
| Time after Starter ON to OFF | 0.5 seconds or more |