Typical Malfunction Thresholds
One of the following conditions is met: Condition (A), (B) or (C)
CONDITION (A): WHEN 2 OR MORE OF THE FOLLOWING SIGNALS ARE INPUT AT THE SAME TIME:
| One of the following conditions is met: | |
| - P position signal | ON |
| - N position signal | ON |
| - Park/neutral position signal | ON |
| R position signal | ON |
| D position signal | ON |
CONDITION (B): ALL OF THE FOLLOWING SIGNALS ARE INPUT AT THE SAME TIME:
| P position signal | OFF |
| N position signal | OFF |
| Park/neutral position signal | OFF |
| R position signal | OFF |
| D position signal | OFF |
CONDITION (C): WHEN ANY OF FOLLOWING CONDITIONS IS MET, THE M POSITION SIGNAL IS ON:
| P position signal | ON |
| N position signal | ON |
| Park/neutral position signal | ON |
| R position signal | ON |