LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Subaru >> 1985 >> GL 2D Hatchback, 1.8 5, Automatic >> Repair and Diagnosis >> Engine Performance >> System >> Air Injection System >> Component Testing >> Check Valve
September 30: LEMON manuals is back up on a temporary server! Slowness is possible

Check Valve

By blowing into check valve, ensure there is no air flow from the intake manifold side to the ASV solenoid valve side. Turn valve around. By blowing into check valve, ensure there is air flow from the ASV solenoid side to the intake manifold side. See Fig 1 .

Fig 1: Sectional View of ASV Check Valve
G40366