LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Subaru >> 2000 >> Forester L F4-2.5L SOHC >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Testing and Inspection >> Scan Tool Testing and Procedures >> Clear Memory Mode >> Subaru Select Monitor (Normal Mode)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Subaru Select Monitor (Normal Mode)

1. On the [Main Menu] display screen, select the {2.Each System Check} and press the [YES] key.
2. On the [System Selection Menu] display screen, select the [Engine Control System] and press the [YES] key.
3. Press the [YES] key after displayed the information of engine type.
4. On the [Engine Diagnosis] display screen, select the [Clear Memory] and press the [YES] key.
5. When the 'Done' and 'Turn Ignition Switch OFF' are shown on the display screen, turn the Subaru Select Monitor and ignition switch to OFF.

NOTE:
- After the memory has been cleared, the ISC must be initialized.To do this, turn the ignition switch to the ON position.Wait 3 seconds before starting the engine.
- For detailed operation procedure, Refer to the SUBARU SELECT MONITOR OPERATION MANUAL.