Section 1 (Generators & Regulators): Overhaul
WARNING: This page is about a different car, the 2000 Subaru Impreza and 2000 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
See Fig 1
for exploded view of generator.
To remove a stuck rear cover after removing case bolts, use soldering iron or heat gun to warm rear cover bearing housing to about 122-140°F (50-60°C). This will expand housing enough to slide cover off rotor bearing. Ensure spring washer located in rear cover bearing bore is not lost during disassembly.