Diagnostic Method
When the rear oxygen sensor output voltage changes from 0.5 V (rich) to 0.15 V (lean), carry out calculation regarding the response time of the output change from 0.45 V to 0.2 V as diagnostic value. When the rear oxygen sensor output voltage does not change from 0.5 V to 0.5 V to 0.15 V, do not carry out calculation even if the output changes from 0.45 V to 0.2 V.
- Abnormality Judgment
Judge NG when the rear oxygen sensor output change response time (diagnostic value) exceeds the threshold value.
Response time > 2 seconds (threshold value) --> Abnormal
Judge NG when all of the malfunction criteria below is completed.
- Judgment Value
- Time Needed for Diagnosis:
4 seconds
- Malfunction Indicator Light Illumination:
Illuminates when malfunction occurs in 2 continuous driving cycles.
- Time Needed for Diagnosis:
- Normality Judgment
Judge OK when the rear oxygen sensor output change response time (diagnostic value) is below the threshold value.
Response time =< 2 seconds (threshold value) --> Normal
Judge NG when the malfunction criteria below is completed.
- Judgment Value
NOTE: Response time is calculated during the deceleration fuel cut in case of abnormal judgment. However, in order to make a normal judgment quickly, diagnosis is performed without deceleration fuel cut.