Diagnostic Method
Calculate the max. value of the amount of output voltage variation from fuel level sensor and cumulative value during 12.8 seconds. Comparing the max value and cumulative value with the threshold value, and judge OK when the both do not go over the threshold value. Otherwise, when one of them goes over the threshold, count the counter up. Judge the ECM is troubled when the counter increased 4 times in a row.
- Abnormality Judgment
Judge NG when the malfunction criteria below are completed.
- Judgment Value
- Time Needed for Diagnosis: 12.8 seconds x 4 times
- Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge OK and clear the NG when all the malfunction criteria below are completed.
- Judgment Value