Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Low side diagnosis (1) | |
| Cumulative time when the malfunction criteria below are completed | >/= 20 seconds |
| Idle switch | OFF |
| Injector pulse | >/= 2.5 milliseconds |
| Engine speed | >/= 2800 rpm |
| Neutral switch | OFF |
| Vehicle speed signals count (353 ms) | < 1 |
Time Needed for Diagnosis:
Low side 20 seconds
Malfunction Indicator Light Illumination: Illuminates as soon as malfunction occurs.