Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Switch signal | OFF (High) |
| "P" range / "N" range on AT | ON |
| Any other switches on AT | OFF |
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Switch signal | ON (Low) |
| "P" range / "N" range on AT | ON |
| Any other switches on AT | OFF |
MT: Judge NG when the number of times until completing the malfunction criteria below continue 3 times in a row, judge OK when turning to OFF or ON.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Neutral switch on MT Driving condition change
|
Not detected Change a) to b) |
Time Needed for Diagnosis:
AT: 5 seconds
MT: 3 monitoring on MT
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.